Vector Graphic Extended Systems Monitor Manual de usuario Pagina 1

Busca en linea o descarga Manual de usuario para Televisores y monitores Vector Graphic Extended Systems Monitor. RApid I nteractive Debugger Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir

Indice de contenidos

Pagina 1 - Debugger

RApid I nteractive Debugger

Pagina 2 - INrERAcrIVE

Vector RAID Reference Manual Rev. l.l-A 5/30/80

Pagina 3 - 1980 by

Vector RAID Reference Manual I. PERSPECrIVE 1.1 The value of RAID Vector Graphic's rrem:)l:Y rrapped systems, such as the System B, offer p:JWerf

Pagina 4 - I reviews

Vector RAID Reference Manual The most significant aspect of this simulation process is that the entirety of ~is information is refreshed on the screen

Pagina 5 - G <address>

Vector FAID Reference Manual .2 'lbe range of· RAID UPon entering RAID, the user is asked where RAID will be located in this session. RAID can be

Pagina 6 - = <opcode>

Vector. RAID Reference Manual 1.3 Protocol used in this manual Underlined naterial is naterial ycu have to type, except where under lining is used for

Pagina 7 - E'

Vector RAID, Reference Manual II. THE ST.RUcruRE OF RAID 2.1 IDading RAID The disk on which RAID comes contains the program which is designed to be us

Pagina 8

Vector RAID Reference Manual ccmnand area. AS soon as yoo tyI::e the fc::::.m: digits, the screen will Ce erased and replaced wi th a large banner r

Pagina 9 - . Page

Vector RAID Reference Manual .2 A RAID session As mentioned in Perspective, simulation is the heart and purpose of RAID. After RAID is loaded, yoo na

Pagina 10 - 5/30/80

Vector RAID Reference Manual 2.3 The RAID display A -drawing of the RAID display is famd at the beginning of this manual, for reference purposes. It

Pagina 11

Vector RAID Reference Manual .4 Ccrrmand area Yoo can type camrancs in the camrand area of the display whenever RAID is in the canrnand node, arx:] th

Pagina 12

RAID -RAPID INrERAcrIVE DEBf]G;ER version 1.1 REFERENCE MANUAL Revision A May 30, 1980 Copyright 1980 vector Graphic Inc.

Pagina 13

Vector RAID Reference Manual 2.5 Instruction area There are seven lines in the instruction area of the screen. Each of these seven lines stxJw one ins

Pagina 14

Vector RAID Reference Manual • 6 CtlInp area: Six lines are in the dump area -of the display. Each line begins with a four-digi t hexadecimal nerrory

Pagina 15 - RAID pt:03ram

Vector RAID Reference Manual 2. 7 Flags and registers Next to the instruction area of the display, there are a group of areas which display the conten

Pagina 16

vector RAID Reference Manual .8 Stack pointer and stack -Along the right side of the display is a colllIlll with the syrrt:cl "SP" at the

Pagina 17 - <RETURN>

Vector RAID Reference Manual 2.9 Halt area The halt area of the display is used in conjuction with the Halt ccmnands 80, BP, arxl EM. 'lbese cam

Pagina 18 - Execute caranands (Xl?

Vector RAID Reference Manual .10 Refresh area Below the halt area is an -area marked with "Rf: n. This is used in conjuction with the XN canrtand

Pagina 19

Vector RAID Reference Manual 2-12 Rev. 1.1-A 5/30/80

Pagina 20

Vector RAID Reference Manual Ycu can t,yt:e carrnands in the camand area of the display whenever RAID is in the ccmma.rrl node, and the two small whi

Pagina 21

vector RAID Reference Manual 3 .1 l?tJmp operations DA. <address> [ <line> [ -] ] IE <address> [ <line> [-] ] There are two

Pagina 22

Vector RAID Reference Manual .2 Enter operations Enter Hex Enter~I Enter Register ElI <address> <byte> [<address> <byte> ••• ]

Pagina 23 - "SP"

Copyright 1980 by Vector Graphic Inc. All rights reserved. DisclaiIrer Vector Graphic makes no representations or warranties with respect to the cont

Pagina 24

Vector RAID Reference Manual 3.3 Fill Fill F <start address> <em address> byte Fills working menot:y with the byte specified fran the star

Pagina 25

Vector RAID Reference Manual .5 Halt operations Halt <:Xl PC Hal t on Opcode Halt at Register Halt at MeIcro:y HP <address> FD <cpccde>

Pagina 26

Vector RAID Reference Manual 3.6 Initialize Screen Initialize Screen I This connnand simply clears any extraneaJS ma.terial off the RAID display. All

Pagina 27 - ConmandS

Vector RAID Reference Manual .7 Load file operations UJad Hex File L <filenaxre>. HEX lJ::)ad Executable File L <filenaxre.file~> These

Pagina 28

Vector RAID Reference Manual 3.8 Set Progtam Counter Set PC P <address> This command simply sets the Progt:am Camter to the desired address. The

Pagina 29 - Enter~I

Vector RAID Reference Manual Quit RAID This transfers control back to the pCo:Jram which called RAID in the first place, which is nocmally the CP/M ex

Pagina 30

Vector RAID Reference Manual 3.10 Stack operations Set Start of Stadt SS <address) '!he Set Start of Stack ct;:eration resets the start of the

Pagina 31 - Be, DE

Vector RAID Reference Manual .11 Execute operations Exeo.lte Slcwly XS [<rate>] This causes simulation to begin at the Program Counter, at the r

Pagina 32 - Initialize

Execute Directly, with specified breakpoints Vector RAID Reference Manual XD [<address> <address> ••• ] (up to 6 addr' s ) This comma

Pagina 33 - UJad Hex

Vector RAID Reference Manual. t12 Help screen Help screen ? This displays the Help screen at any tine by simply inpltting a question nm:::k \tIhen the

Pagina 34 - <address>

FOREWJRD Audience S<:q?e Organization This manual is intended for ASSEMBLY LANGUAGE progranurers. It assurres an in depth kncwledge of t..l)e ZaD C

Pagina 35

Vector RAID Reference Manual Loading RAID RAID [<d:filename>.HEX] Load file operations L <d:filename.file~> L <d:filename>.HEX Tr

Pagina 36 - <word>

Halts during simulation -HP <address> HO <opcode> HR <register or pair> <value> HM <address> <byte> DA <addres

Pagina 37 - XF command, XP

Vector RAID Reference Manual canmand P flags**** instruction area: A * 2 instructions just exeOlted, then B contents Olrrent instruction, then the C o

Pagina 38 - Execute

vector RAID Reference Manual Rev. l.l-A 5/30/80

Pagina 39

Vector RAID Reference Manual Section SUImal:Y of RAID Ccnmmds RAID Display Table of Contents I • Perspective 1.1 The value of RAID 1.2 The ra.n;e of

Comentarios a estos manuales

Sin comentarios